General |
Microplate Types |
96-, 384- and 1536-well
Low profile and standard height
Solid and filter bottom (option) |
Onboard Software |
Create, edit or run multiple protocols |
Software (pc control) |
LHC2 Software
LHC2 Secure for 21 CFR Part 11 compliance (option)
SiLA Compliant driver (option) |
Separation |
Biomagnetic separation, vacuum filtration (optional) |
Shaking |
Programmable up to 60 minutes
Slow, medium, fast or variable |
Soaking |
Programmable up to 60 minutes |
Ultrasonic Advantage™ |
Standard on most configurations |
Automation |
BioStack and 3rd party automation compatible
BioSpa 8 Automated Incubator compatible |
Washing |
Manifold Types |
96-well washing: 96-tube manifold - straight dispense tubes
96- and 384-well washing: 96-tube Dual-Action manifold - 20° angled dispense tubes
384-well washing (fast): 192-tube Dual-Action manifold - 7° angled dispense tubes
1536-well washing: Two 32-tube dispense manifolds - 7° angled dispense tubes |
Volume Range |
3 - 3,000 µL/well in 1 µL increments |
Wash Cycles |
1 - 250 |
Buffer/reagent selection |
Auto switching module for up to 4 buffers (option) |
Supply Bottle |
4 L or 10 L (optional) |
Dispense Accuracy |
+3% |
Dispense Precision |
<3% CV (model dependent) |
Residual Volume |
<2 µL/well |
Wash Speed |
96 wells, 300 µL/well, 96-tube manifold: 13 seconds
384 wells, 100 µL/well, 192-tube manifold: 17 seconds
1536 wells, 10 µL/wells, two 32-tube manifolds: 36 seconds |
Flow Rates |
High flow to low flow
Optimized rates for cell assays |
Sterilization |
Chemical |
Vacuum range for filtration |
Selectable: 0 to -380 mmHg (final at 30s)
Filtration time: 5 - 999 seconds |
Dispensing - Peristaltic pump (Multi-Channel) |
Manifold Types |
8-tip (1 x 8) cassette with plastic, 316 SS tubes or sapphire jeweled 316 SS tubes |
Fluid Delivery |
1 or 2 peristaltic pumps |
Dispense Speed |
96 wells, 10 µL /well: 8 seconds
384 wells, 5 µL /well: 12 seconds
1536 wells, 1 µL /well: 27 seconds |
Volume Range |
500 nL - 3,000 µL/well, selectable in 1 µL increments |
Flow Rates |
User programmable rates from high to low
Optimized rates for cell assays |
Dispense Performance |
1 µL cassette:
Recommended Volume Range: 1 - 50 µL
Dispense Accuracy: +5% at 1 µL
Dispense Precision: <5% CV at 1 µL
<10% CV at 500 nL
Minimum Prime Volume: 1.20 mL
5 µL cassette:
Recommended Volume Range: 5 - 2,500 µL
Dispense Accuracy: +2.0% at 5 µL
Dispense Precision: <2.5% CV at 5 µL
Minimum Prime Volume: 4.23 mL
10 µL cassette:
Recommended Volume Range: 10 - 3,000 µL
Dispense Accuracy: +2.0% at 10 µL
Dispense Precision: <2.0% CV at 10 µL
Minimum Prime Volume: 7.36 mL |
Recommended cassette replacement interval |
1 µL Cassette: 1,000 384-well microplates at 5 µL well
5 µL Cassette: 1,000 96-well microplates at 50 µL well
10 µL Cassette: 1,000 96-well microplates at 100 µL well |
Sterilization |
Autoclave, chemical |
Dispensing - Syringe pump |
Manifold Types |
96-well dispensing:
One 16-tube (2 x 8) manifold - 316 SS tubes
96-/384-well dispensing:
Two 16-tube (1 x 16) manifolds - 316 SS tubes
1536-well dispensing:
Two 32-tube (1 x 32) manifolds - sapphire jeweled 316 SS or 316 stainless steel tubes |
Fluid Delivery |
Two positive displacement syringe drives |
Dispense Speed |
20 µL /well, 96 wells, 1 x 16 tubes: 5.25 seconds
20 µL /well, 384 wells, 1 x 16 tubes: 14 seconds
3 µL /well 1536 wells, 2 x 32 tubes: 7 seconds |
Volume Range |
3 - 3,000 µL/well, selectable in 1 µL increments
Minimum Prime Volume: 12 mL |
Flow Rates |
User programmable rates from high to low |
Dispense Accuracy |
+1 µL at 5 µL
+1 µL at 20 µL
+1% at 100 µL |
Dispense Precision |
<5% CV at 5 µL
<2.5% CV at 20 µL
<1% CV at 100 µL |
Supply Bottle |
1 L or 2 L |
Sterilization |
Chemical, autoclavable option |
Physical Characteristics |
Power |
100 - 240 Volts AC. 50/60 Hz |
Dimensions |
16.5" W x 18" D x 12.5" H (42 x 46 x 32 cm) |
Weight |
32 lbs (14.5 kg) |
Regulatory |
Regulatory |
CE and TUV marked. ROHS compliant. In Vitro Diagnostic use
models are available. |